©2009 Twin City Fan Companies, Ltd.
Fan sizes 21 to 36 are shipped fully assembled, unless otherwise specified.
A minimum of two people are required for assembly. Before starting, review these instructions.
The following tools are required:
- Powered screwdriver (preferred), or drill
- 3/8, 7/16, 1/2, 9/16 wrenches and sockets
- 5/16" nut driver bit for powered screwdriver
- Awl, for hole alignment
Panel End
Assembly,
Female
Panel End
Assembly,
Male
Hood Panel
Stiffener Angle
Hood Mount Bar
Hood Side Rail Assembly
Filter Rail
Filter Rail Assembly, Long
Hood Clip
(Size 54 and 60)
Stiffener
Angle
Hood Mount Bar
Filter Rail Assembly, Short
Filter Rail Assembly, Short
Hood
Side Rail
Assembly
Filter Rail
Filter
Rail
Assembly,
Long
Fan
Base
Assembly
Filter Stop Plate
Filter Stop Plate
Hood Gusset
Inspect for missing or damaged parts
Fan Size/Qty
21 24 30 36 42 48 54 60
Panel End Assy, Male 1 1 1 1 1 1 1 1
Panel End Assy, Female 1 1 1 1 1 1 1 1
Hood Panel 2 3 5 5 6 7 8 9
Hood Side Rail Assy 2 2 2 2 2 2 2 2
Filter Rail Assy, Long 2 2 2 2 2 2 2 2
Filter Rail Assy, Short 0 2 2 2 2 2 2 2
Filter Rail 2 2 2 2 2 2 2 2
Hood Gusset 0 0 4 4 4 4 4 4
Stiffener Angle 2 2 2 2 2 2 2 2
Filter Stop Plate 2 2 2 2 2 2 2 2
Hood Clip 0 0 0 0 0 0 18 20
Hood Mount Bar 2 2 2 2 2 2 2 2
Filter Size A 4 6 8 8 8 10 10 10
Filter Size B 2 4 4 4 4 4 8 8
HDWRKIT-LH07 Hardware Kit #7 - Filter Rail
Qty Item
22 Cap Screw, Serrated Flange, 5/16-18 x .75
16 Hex Nut, Serrated Flange, 5/16-18
6 Nut Clips, 5/16
HDWRKIT-LH01 Hardware Kit #1 - Hood
Qty Item
12 Cap Screw, Serrated Flange Hex, 3/8-16 x .75
20 Hex Nut, Serrated Flange, 3/8-16
4 Cap Screw, Serrated Flange Hex, 3/8-16 x 1.25
72 Screws, #12
IM-4860FS
September 2009
Hooded Propeller Roof Fans
(Filtered Supply)
INSTALLATION & ASSEMBLY MANUAL
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - IM-4860FS

©2009 Twin City Fan Companies, Ltd.• Fan sizes 21 to 36 are shipped fully assembled, unless otherwise specified.• A minimum of two people are required

Page 2 - End View of Panel

2 Twin City IM-4860FS Twin City IM-4860FS 3Step 1 – Install Hood Mount Bars and Filter StopsFasteners (Kit #1): Cap Screw, Serrated Flange, 3

Page 3

2 Twin City IM-4860FS Twin City IM-4860FS 3Step 1 – Install Hood Mount Bars and Filter StopsFasteners (Kit #1): Cap Screw, Serrated Flange, 3

Page 4 - Filter Configurations

Step 7 – Install End Assembly (Female)Fasteners (Kit #1): Screws, #12A. Assemble End Panel Assembly (female type) using four #12 screws. On s

Commentaires sur ces manuels

Pas de commentaire